ATIVAÇÃO DO MÚSCULO DELTOIDE EM EXERCÍCIOS DE OMBRO
Abstract
Shoulder is widely considered the human most instable articular complex. The three portions of deltoid muscle, anterior, medium and posterior have great responsibility in stabilize the joint. The aim of this study was to evaluate anterior (AD) and posterior (PD) deltoid muscle activation during different exercises using surface electromyography. Participate in the study one male subject, 26 years old, 82 kg weight and 1,84 m height. There were evaluated supine, fly, lateral and frontal raise exercises with a 5 kg external load. Bipolar electrodes were positioned on anterior and posterior deltoid muscle portions with 2.5 cm space centre-centre. A reference electrode was positioned on ulna styloid process. We used a 1000 Hz sample frequency. Signals were filtered with a 3 order Butterworth and made cuttings for concentric movement phases. The software SAD32 was used for all data procedures. The analyses were achieved with mean RMS values from three repetitions concentric phase. The following muscle activation results were observed: supine: supino 0.059 for AD and 0.044 for DP; fly 0.054 for AD and 0.045 for PD; frontal raise 0.371 for AD and 0.169 for PD; lateral raise 0.367 for AD and 0.174 for PD. We observed the raising exercises presented higher activation values, probably due to the distance between load and joint Center of rotation. In conclusion the raising exercises generate greater activation for the same external load
Downloads
References
BASMAJIAN, J. V.; DE LUCA, C.J.; Muscle Alive: Their Function Revealed By Electromyography. 5ª Ed. Baltimore: Williams and Wilkins, 65-100, 1985.
BECK, T.W.; HOUSH, T. J.; JOHNSON, G. O.; WEIR, J. P.; CRAMER, J. T.; COBURN, J. W.; MALCK, M. H.; The effects of interelectrode distance on electromyographic amplitude and mean power frequency during isokinetic and isometric muscle actions of the biceps brachii. Journal of Electromyography Kinesiology, 2005; 15:482-495.
DURWARD, B. R.; BAER, G. D.; ROWE, P. J.; Movimento Funcional Humano – Mensuração e Análise. São Paulo: Manole, 2001.
ENOKA, R. M.; Bases Neuromecânicas da Cinesiologia. 2ª Ed. São Paulo: Manole, 2000.
KAPANDJI, A. I.; Fisiologia Articular: Membro Superior. São Paulo: Panamericana, 2000.
HUXLEY, A.F.; Muscle Structure and Theories of Contraction. Prog Biophysics and Chemistry, 7: 255318, 1957.
INMAN, V. T.; SAUNDERS, J. B.; ABBOTT, L. C.; Observations on the function of the shoulder joint. Journal of Bone and Joint Surgery, 26: 1-30, 1944.
LIEBER, R. L.; FRIDÉN, J.; Functional and clinical significance of skeletal muscle architecture. Muscle & Nerve, 23: 1647-1666, 2000.
NETTER, F. H.; Atlas de anatomia humana. 3ª ed. Porto Alegre: Artmed, 2003.
NIGG, B.; HERZOG, W.; Biomechanics of the Muscle-Skeletal System. Toronto. John Wiley & Sons, 1994.
NORDIN, M.; FRANKEL, V. H.; Biomecânica Básica do Sistema Musculoesquelético. Rio de Janeiro: Guanabara Koogan, 2003.
OKUNO, E.; FRATIN, L.; Biomecânica: Desvendando a Física do Corpo Humano. São Paulo: Manole, 2003.
OLIVEIRA, A. S.; RODRIGUES, D.; BÉRZIN, F.; Avaliação Eletromiográfica do Músculo Deltóide em Movimentos de Abdução do Ombro – Alterações Relacionadas ao Envelhecimento. In: Congresso Brasileiro de Biomecânica (Gramado, 9, 2001). Anais. Porto Alegre: ESEF UFRGS, 2001. 2v.
PINTO, L. C.; Eletromiografia clínica. 1ª ed. São Paulo: Atheneu, p.19-45, 1996.
PINTO, R. S.; LIMA, C. S.; Cinesiologia e Musculação. Porto Alegre: Artmed, 2006.
SODEBERG, G. L.; COOK, T. M.; Electromyography in biomechanics. Journal of Orthopedics and. Physical Therapy, 64, 1984.
SULLIVAN, O.; SUSAN, B.; SCHIMITZ, T.J.; Fisioterapia Avaliação e tratamento. 2ª ed. São Paulo: Manole, 1993.
PR 153, Km 7, s.n., Riozinho Irati/PR 84500-000
Downloads
Published
Issue
Section
License
Copyright (c) 2010 Research Collection in Physical Education

This work is licensed under a Creative Commons Attribution 4.0 International License.
This work is licensed under a Creative Commons Attribution 4.0 International License (CC BY 4.0).
Authors retain copyright and grant the journal the right of first publication. Under this license anyone may copy, redistribute, adapt and build upon the material, in any medium or format and for any purpose, including commercial use, provided that appropriate credit is given to the authors and to Coleção Pesquisa em Educação Física, with a link to the license and an indication of any changes made.
Published works are the sole responsibility of their authors and do not necessarily reflect the position of the journal or of Fontoura Editora.