ANALYSIS AND COMPARISON BETWEEN BIOIMPEDANCE ELECTRICAL AND THICKNESS OF SKIN FOLDS TO ESTIMATE OF PERCENTAGE OF BODY FAT IN BODYBUILDERS

Authors

  • Luís Henrique Sales Oliveira Author
  • Flávio Eduardo do Prado Author
  • Ronaldo Júlio Baganha Author
  • Alexandre de Souza e Silva Author
  • Rodolfo Malagó Author
  • Pâmela Camila Pereira Author

Keywords:

Muscle, Subcutaneous fat, Body fat distribution

Abstract

Currently there are different ways to assess body composition of physical exercise practitioners among them we can mention the techniques of bioimpedance and skinfolds. The aim of this study was to analyse and compare the percentage of body fat bodybuilders with methods of bioelectrical impedance and skinfold thickness (anthropometric). Study participants were 40 students of the Academy Vital Energy in the city of Pouso Alegre/MG aged between 18 and 30 years, bodybuilders at least six months. Anthropometric variables, body mass, height and four skinfolds (triceps, abdominal, suprailiac and medial thigh) were measured. With anthropometric variables was estimated body fat percentage using the equation proposed by Jackson; Pollock (1978). And the measurement of the bioimpedance analyzer Tanita ® Slim. To collect data, a digital scale with the Toledo® brand unit of measurement of 0.1 kg to obtain the body mass of Sanny stadiometer unit mark with 0.1 cm to obtain height and caliper of Sanny brand was used for obtaining measurements of skinfold thickness. For data analysis we used the Microsoft Office Excel Software 2007, Student’s t test for paired samples with a significance level of 5% (p ≤ 0.05), followed by Pearson correlation to determine the coefficient (r) correlation between methods. The results showed statistically significant differences for estimate the fat percentage (P ≤ 0.05) between the methods and the anthropometric method by skinfold thickness seems to be a better option for estimating percentage body fat when compared to BIA due to its ease of application and handling equipment

Views: 178Downloads: 34

Downloads

Download data is not yet available.

References

BUSCARIOLO, F.F., CATALANI, M.C., DIAS, L.C.G.D., NAVARRO A.M. Comparação entre os métodos de bioimpedancia e antropometria para avaliação da gordura corporal em atletas do time de futebol feminino de Botucatu-SP. Revista Simbio-Logias. v. 1, n. 1, p. 122-129, 2008.

BRITTO, E.P., MESQUITA, E.T. Bioimpedância elétrica aplicada à insuficiência cardíaca. Rev SOCERJ. v. 21, n. 3, p.178-183, 2008.

CARVALHO, A.B.R.; PIRES NETO, C.S. Composição corporal através dos métodos de pesagem hidrostática e impedância bioelétrica em universitários. Revista Brasileira de Cineantropometria e Desempenho Humano. v. 1, n. 1, p. 18-23, 1999.

COCETTI, M., CASTILHO, S.D., BARROS FILHO, A.A. Dobras cutâneas e bioimpedância elétrica pernaperna na avaliação da composição corporal de crianças. Revista de Nutrição. Campinas, v. 22, n. 4, p. 527-536, 2009.

COQUEIRO, R.S.; PETROSKI, E.L.; PELEGRINI, A.; BARBOSA, A. R. Insatisfação com a imagem corporal: avaliação comparativa da associação com estado nutricional em universitários. Rev. psiquiatr. Rio Gd. Sul. v. 30, n. 1, p. 31-38,2008.

CYRINO, E.S.; OKANO, A.H.; GLANER, M.F.; ROMANZINI, M. GOBBO, L.A.; MAKOSKI, A.; BRUNA, N.;

MELO, J.C.; TASSI, G.N. Impacto da utilização de diferentes compassos de dobras cutâneas para análise da composição corporal. Revista Brasileira de Medicina do Esporte. v. 9 n. 3, p. 145-149, 2003.

EICKEMBERG, M.; OLIVEIRA, C.C.; RORIZ, A.K.C; SAMPAIO, L.R. Bioimpedância elétrica e sua aplicação em avaliação nutricional. Revista de Nutrição. Campinas, v. 24, n. 6, p. 883-893, 2011.

FETT, C.A., FETT, W.C.R., OYAMA, S.R., MARCHINI, J.S. Composição corporal e somatótipo de mulheres com sobrepeso e obesas pré e pós-treinamento em circuito ou caminhada. Revista Brasileira de Medicina do Esporte. v. 12, n. 1, p. 45-50, 2006.

GLANER, M.F. Índice de massa corporal como indicativo da gordura corporal comparado às dobras cutâneas. Revista Brasileira de Medicina do Esporte. v. 11, n. 04, p. 243-246, 2005.

GLANER, M.F.; RODRIGUEZ AÑEZ, C.R. Validação de procedimentos antropométricos para estimar a densidade corporal e percentual de gordura em militares masculinos. Revista Brasileira de Cineantropometria e Desempenho Humano. v. 4, n. 1, p. 24-29, 1999.

HRABOSKY J.I., GRILO, C.M. Body image and eating disordered behavior in a community sample of Black and Hispanic women. Eat Behav. v. 8, n. 1, p. 106-14, 2007.

HEYWARD V., STOLARCZYK L. Avaliação da composição corporal aplicada. São Paulo: Manole, 2000.

JACKSON, A.S.; POLLOCK, M.L. Generalized equations for predicting body density of men. Br J Nutrition, v. 40, p. 497-504, 1978.

HERNANDES JR, B.D.O. Treinamento desportivo. Rio de Janeiro: Sprint, 2000.

KENNEDY, W.L.; WILMORE, J.H.; COSTILL, D.L. Fisiologia do Esporte e do Exercício. 5. ed. Barueri, SP: Manole, 2013.

MCARDLE, W.D.; KATCH, F.I.; KATCH, V.L. Fisiologia do exercício, energia, nutrição e desempenho Humano. 7 ed. Rio de Janeiro, RJ: Guanabara Koogan, 2011.

MARTINS, K.A.; MONEGOI, E.T.; PAULINELLI, R.R.; FREITAS-JUNIOR, R. Comparação de métodos de avaliação da gordura corporal total e sua distribuição. Revista Brasileira de Epidemiologia. v. 14, n. 4, p. 677-687, 2011.

PAIVA, C.R.E.; GAYA, A.C.A; BOTTARO, M.; MIRANDA NETO, J.T. Bioimpedância versus absortometria radiológica de dupla energia na avaliação da composição corporal em crianças. Unimontes Científica. v. 3, n.3 , p.1-10, 2002.

REZENDE, F.A.C., ROSADO, L.E.F.P.L., FRANCESCHINNI, S.C. C., ROSADO, G.P., RIBEIRO, R.C.L. Aplicabilidade do índice de massa corporal na avaliação da gordura corporal. Revista Brasileira de Medicina do Esporte. v. 16, n. 2, p. 90-94, 2010.

REZENDE, F.; ROSADO, L.; FRANCESCHINNI, S.; ROSADO, G.; RIBEIRO, R.; MARINS, J.C.B. Revisão crítica dos métodos disponíveis para avaliar a composição corporal em grandes estudos populacionais e clínicos. Arquivos Latino americano de Nutrição. v. 57, n. 4, p. 327-334, 2007.

RODRIGUES, N.M.; SILVA, S.C.; MONTEIRO, W.D.; FARINATTI, P.T.V. Estimativa da gordura corporal através de equipamentos de bioimpedância, dobras cutâneas e pesagem hidrostática. Revista Brasileira de Medicina do Esporte. v. 7 n. 4, p. 125-131, 2001.

ROSSI, L., TIRAPEGUI, J. Comparação dos métodos de bioimpedância e equação de Falkner para avaliação da composição corporal em desportistas. Revista Brasileira de Ciências Farmacêuticas. v. 37, n. 2, p. 137-142, 2001.

TRIBESS, S.; PETROSKI, E.L.; RODRIGUEZ-AÑEZ, C.R. Percentual de gordura em praticantes de condicionamento físico pela impedância bioelétrica e pela técnica antropométrica. Lecturas Educación Física y Deportes. Buenos Aires, v. 09, n. 64, p. 01-10, 2003. Disponível em <http://www.efdeportes.com/ efd64/antrop.htm>. Acesso em: 08 jul. 2014.

______________________ 1 Centro Universitário de Itajubá - FEPI. 2 Universidade do Vale do Sapucaí - Univás. Rua Doutor Antônio Braga Filho, 687 Varginha Itajubá/MG 37501-002

Published

2014-01-01

How to Cite

Oliveira, L. H. S., Prado, F. E. do, Baganha, R. J., Silva, A. de S. e, Malagó, R., & Pereira, P. C. (2014). ANALYSIS AND COMPARISON BETWEEN BIOIMPEDANCE ELECTRICAL AND THICKNESS OF SKIN FOLDS TO ESTIMATE OF PERCENTAGE OF BODY FAT IN BODYBUILDERS. Research Collection in Physical Education, 13(4), 39-46. https://rcpef.org/cpef/article/view/1130

Similar Articles

1-10 of 50

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)